Loading
Products & Specifications
PERFORMANCE
Weight Per
Square Yard

Weight Per
Square Yard

Weight Per
Square Yard

Weight Per
Square Yard
Product Specifications Test Procedure 24 oz. 28 oz. 32 oz. 40 oz.
Width 6’ 6’ 6’ 6’
Length 60’ 60’ 60’ 60’
Weight per Square Yard ASTM D3776 24 oz. 28 oz. 32 oz. 40 oz.
Roll Weight 60 lb. 70 lb. 80 lb. 100 lb.
Density (lb.cu.ft.) approx. 6.5 lb. 7.0 lb. 7.3 lb. 8.0 lb.
Thickness FTMS 191 5/16” 3/8” (Prox) 3/8” 7/16”
Tear Strength ASTM 2262 40 lb. 42 lb. 44 lb. 46 lb.
Elongation Tests ASTM D3574 13% avg. 13% avg. 13% avg. 13% avg.
Foot Traffic ASTM 2401 300k min. Pass Pass Pass Pass
Acoustical NRC ASTM C423-77 0.66 0.68 0.69 0.74
Insulation “R” Factor ASTM C518-76 2.19 2.24 2.29 2.39
Order / Mildew AATCC 174 Part III None None None None
Static Load Test 1 hour 97.5% Recovery 97.5% Recovery 97.5% Recovery 97.5% Recovery
Static Load Test 24 hour 98.3% Recovery 98.3% Recovery 98.3% Recovery 98.3% Recovery
FHA / HUD UM 72 – A Pass Class I Pass Class II Pass Class II Pass Class III
Smoke Density ASTM E662 Pass Pass Pass Pass
Flammability Pill Test DOC-FF-1-70 Pass Pass Pass Pass
Fiber Content 100% Post Consumer Recycled Synthetic Carpet Fiber 100% Post Consumer Recycled Synthetic Carpet Fiber 100% Post Consumer Recycled Synthetic Carpet Fiber 100% Post Consumer Recycled Synthetic Carpet Fiber 100% Post Consumer Recycled Synthetic Carpet Fiber
Radiant Panel ASTME-648 Class I Class I Class I Class I
PERFORMANCE PLUS
Weight Per
Square Yard

Weight Per
Square Yard

Weight Per
Square Yard
Product Specifications Test Procedure 28 oz. 32 oz. 40 oz.
Width 6’ 6’ 6’
Length 60’ 60’ 60’
Weight per Square Yard ASTM D3776 28 oz. 32 oz. 40 oz.
Roll Weight 70 lb. 80 lb. 100 lb.
Density (lb.cu.ft.) approx. 7.5 lb. 8.5 lb. 8.9 lb.
Thickness approx. FTMS 191 5/16” (Prox) 5/16” 3/8”
Tear Strength ASTM 2262 42 lb. 44 lb. 46 lb.
Elongation Tests ASTM D3574 13% avg. 13% avg. 13% avg.
Foot Traffic ASTM 2401 300k min. Pass Pass Pass
Acoustical NRC ASTM C423-77 0.68 0.69 0.74
Insulation “R” Factor ASTM C518-76 2.24 2.29 2.39
Order / Mildew AATCC 174 Part III None None None
Static Load Test 1 hour 97.5% Recovery 97.5% Recovery 97.5% Recovery
Static Load Test 24 hour 98.3% Recovery 98.3% Recovery 98.3% Recovery
FHA / HUD UM 72 – A Pass Class II Pass Class II Pass Class III
Smoke Density ASTM E662 Pass Pass Pass
Flammability Pill Test DOC-FF-1-70 Pass Pass Pass
Fiber Content 100% Post Consumer Synthetic Carpet Fiber 100% Post Consumer Synthetic Carpet Fiber 100% Post Consumer Synthetic Carpet Fiber 100% Post Consumer Synthetic Carpet Fiber
Radiant Panel ASTM E-648 Class I Class I Class I