Loading
Products & Specifications
PERFORMANCE PLUS Download PDF
Weight Per
Square Yard
Download PDF
Weight Per
Square Yard
Download PDF
Weight Per
Square Yard
Product Specifications Test Procedure 28 oz. 32 oz. 40 oz.
Width 6’ 6’ 6’
Length 60’ 60’ 60’
Weight per Square Yard ASTM D3776 28 oz. 32 oz. 40 oz.
Roll Weight 70 lb. 80 lb. 100 lb.
Density (lb.cu.ft.) approx. 7.5 lb. 8.5 lb. 8.9 lb.
Thickness approx. FTMS 191 5/16” (Prox) 5/16” 3/8”
Tear Strength ASTM 2262 42 lb. 44 lb. 46 lb.
Elongation Tests ASTM D3574 13% avg. 13% avg. 13% avg.
Foot Traffic ASTM 2401 300k min. Pass Pass Pass
Acoustical NRC ASTM C423-77 0.68 0.69 0.74
Insulation “R” Factor ASTM C518-76 2.24 2.29 2.39
Order / Mildew AATCC 174 Part III None None None
Static Load Test 1 hour 97.5% Recovery 97.5% Recovery 97.5% Recovery
Static Load Test 24 hour 98.3% Recovery 98.3% Recovery 98.3% Recovery
FHA / HUD UM 72 – A Pass Class II Pass Class II Pass Class III
Smoke Density ASTM E662 Pass Pass Pass
Flammability Pill Test DOC-FF-1-70 Pass Pass Pass
Fiber Content 100% Post Consumer Synthetic Carpet Fiber 100% Post Consumer Synthetic Carpet Fiber 100% Post Consumer Synthetic Carpet Fiber 100% Post Consumer Synthetic Carpet Fiber
Radiant Panel ASTM E-648 Class I Class I Class I
PERFORMANCE
DOUBLE STICK
Download PDF
Weight Per
Square Yard
Download PDF
Weight Per
Square Yard
Download PDF
Weight Per
Square Yard
Product Specifications Test Procedure 28 oz. 32 oz. 40 oz.
Width 6’ 6’ 6’
Length 60’ 60’ 60’
Weight per Square Yard ASTM D3776 28 oz. 32 oz. 40 oz.
Roll Weight 70 lb. 80 lb. 100 lb.
Density (lb.cu.ft.) approx. 9.3 lb. 8.5 lb. 8.9 lb.
Thickness approx. FTMS 191 1/4” 5/16” 3/8”
Tear Strength ASTM 2262 42 lb. 44 lb. 46 lb.
Elongation Tests ASTM D3574 13% avg. 13% avg. 13% avg.
Foot Traffic ASTM 2401 300k min. Pass Pass Pass
Acoustical NRC ASTM C423-77 0.68 0.69 0.74
Insulation “R” Factor ASTM C518-76 2.24 2.29 2.39
Order / Mildew AATCC 174 Part III None None None
Static Load Test 1 hour 97.5% Recovery 97.5% Recovery 97.5% Recovery
Static Load Test 24 hour 98.3% Recovery 98.3% Recovery 98.3% Recovery
FHA / HUD UM 72 – A Pass Class II Pass Class II Pass Class III
Smoke Density ASTM E662 Pass Pass Pass
Flammability Pill Test DOC-FF-1-70 Pass Pass Pass
Fiber Content 100% Post Consumer Synthetic Carpet Fiber 100% Post Consumer Synthetic Carpet Fiber 100% Post Consumer Synthetic Carpet Fiber 100% Post Consumer Synthetic Carpet Fiber
Radiant Panel ASTM E-648 Class I Class I Class I
Indoor Air Quality – Version/Revision 2.0 Nov 10, 2015 (Meets or Exceeds All Green Labeling Emissions Criteria. A Non V.O.C. Emitter.)